What's New on Westgard Web: June 2019 - Blog - Westgard QC

Tools, Technologies and Training for Healthcare Laboratories

What's New on Westgard Web: June 2019

Posted by Sten Westgard, MS

Here is what is new on the Westgard.com:

Missing the targets
Fca5f02a 4114 45d6 9d95 B26debfceafeThe biggest development in analytical performance specification (APS) is upon us. At the IFCC WorldLab meeting in Barcelona, the EFLM unveiled the next generation of biological variation specifications. Rigorously screened studies, through the use of the EuBIVAC checklist, now inform the setting of targets for analytical performance.

This is a major advance. It is a testament to the dedicated efforts of EFLM to produce the database after 5 years of hard work.

The next question to tackle: are these new goals so tight we can't hit them? Are some of our methods so bad they can't even meet the old goals? (See below, for examples...)

See the new EFLM database on biological variation

See a summary of APS derived from recent meta-analyses of biological variation studies.
  



An AU5800 in India

Bdf11dac Ed66 418f A48b A000f5d70c81
A recent study of an AU 5800 in a hospital in Hyderabad, India, raises questions about how instruments perform in a more challenging environment.

Are performance problems shown here from the lab, from the instrument, or from both?
 



ADVIA Centaur XPT Thyroid Testing in India

7a5d97bc Fb6e 4faa 9d77 11cd36b08b57
A recent study of an ADVIA Centaur XPT in a hospital in Hyderabad, India, raises questions about how instruments perform in a more challenging environment.

Are performance problems shown here from the lab, from the instrument, or from both?
 


TT4 Testing Performance Comparison

C8b546c1 9a87 48ed 9266 Bf284f7043f5
A recent study of the automated immunoassay methods compared the major diagnostic instruments against a ID-LCMS reference method.

When compared to the "true values", can any methods hit the most evidence-based (but old) biological variation-derived performance specifications?

Can any methods hit the minimum performance specifications, for that matter?

 


Lishui General Hospital Sigma Verification of Performance

Fda93ae5 F55c 4498 9ff8 43f73b5f0cee

Zhejiang Lishui Central Hospital Laboratory is the latest laboratory to join the ranks of Sigma Verification.
 


-----

×
Stay Informed

When you subscribe to the blog, we will send you an e-mail when there are new updates on the site so you wouldn't miss them.

Westgard in the News: Shaking up QC Frequency
Six Sigma Metrics ... Surging in China
 

Comments

No comments made yet. Be the first to submit a comment
Already Registered? Login Here
Thursday, 22 October 2026

Let us know what you're interested in!

Please use this form to request more information about.

Westgard Products and Services.

Invalid Input
Invalid Input
Invalid Input
Invalid Input