Tools, Technologies and Training for Healthcare Laboratories

Ramathibodi Hospital Sigma Verification of Performance

Ramathibodi Hospital has succeeded in joining the Westgard Sigma Verification of Performance Program (Sigma VP). Verified since 2015, they continue to expanded their verification, including more assays, more instruments and even an additional laboratory in 2016.

Ramathibodi Hospital - Sigma Verification of Performance

Duration of Verification: May 31st, 2022 through June 30th, 2023
Verified since December 2015

In 2015 and 2016, Westgard QC was pleased to verify the performance of 29 assays on one instrument at Ramathibodi Hospital. In subsequent years, they have expanded their implementation of sigma metrics.

 Ramathibodi Hospital

Following the Second National Economic and Social Development Plan (1964-1966), the Thai Government aimed to increase the number of doctors and nurses in order to meet the needs of the country. In August 1964, the Cabinet approved the plan of setting up a new medical school which would be located around the Phyathai area, Bangkok, Thailand. HM King Bhumibol Adulyadej graciously conferred the name on the new school of medicine “Ramathibodi” and laid the foundation stone for the building on December 30th, 1965. Four years later, the King came to open the new faculty of medicine on May 3rd, 1969. Apart from the Government’s fund, the Faculty was financially and academically supported by the Rockefeller Foundation from the United States of America. Since then the Faculty of Medicine Ramathibodi Hospital has been fully equipped and has provided medical education and research facilities to the public. Moreover, it serves patients in Bankgok and from all over Thailand.

http://med.mahidol.ac.th/en/aboutus/hospital-and-services-en

Performance of Ramathibodi Hospital

Chemistry Assays

SDMC Alinity C (A1) Verified

SDMC Alinity C (A2) Verified

Albumin

Six Sigma

Six Sigma

Alk Phos

Five Sigma

Six Sigma

ALT

Four Sigma

Six Sigma

AST

Six Sigma

Six Sigma

Bilirubin, Direct

Six Sigma

Six Sigma

Bilirubin, Total

Four Sigma

Six Sigma

Calcium

Four Sigma

Four Sigma

Chloride

Five Sigma

Four Sigma

Cholesterol

Six Sigma

Six Sigma

Creatinine

Six Sigma

Six Sigma

Creatinine Kinase (CK)

Four Sigma

-

CO2

Four Sigma

Four Sigma

GGT

Six Sigma

Six Sigma

Glucose

Six Sigma

Five Sigma

HDL

Four Sigma

Six Sigma

LDL

Six Sigma

Six Sigma

Magnesium

Four Sigma

-

Phosphorous

Four Sigma

Six Sigma

Potassium

Six Sigma

Six Sigma

Protein, Total

Six Sigma

Six Sigma

Sodium

-

Four Sigma

Triglycerides

Six Sigma

Six Sigma

Urea Nitrogen

-

Four Sigma

Uric Acid

Six Sigma

Six Sigma

 

Chemistry Assays

SDMC Alinity C (B1) Verified

SDMC Alinity C (B2) Verified

Albumin

Six Sigma

Six Sigma

Alk Phos

Five Sigma

Six Sigma

ALT

Four Sigma

Six Sigma

AST

Six Sigma

Six Sigma

Bilirubin, Direct

Six Sigma

Six Sigma

Bilirubin, Total

Four Sigma

Six Sigma

Calcium

Six Sigma

Six Sigma

Chloride

Five Sigma

Four Sigma

Cholesterol

Six Sigma

Six Sigma

Creatinine

Six Sigma

Six Sigma

Creatinine Kinase (CK)

Five Sigma

-

CO2

-

Four Sigma

GGT

Six Sigma

Six Sigma

Glucose

Six Sigma

Six Sigma

HDL

Six Sigma

Six Sigma

LDL

Six Sigma

Six Sigma

Magnesium

Four Sigma

-

Phosphorous

Four Sigma

Six Sigma

Potassium

Six Sigma

Six Sigma

Protein, Total

Six Sigma

Six Sigma

Sodium

Four Sigma

Four Sigma

Triglycerides

Five Sigma

Six Sigma

Urea Nitrogen

Four Sigma

Four Sigma

Uric Acid

Six Sigma

Six Sigma

Ramathibodi has also verified the Sigma metrics of its immunoassays.

Visual Performance of Ramathibodi Hospital

 2022 rama sdmc nmedx 1

2022 rama sdmc nmedx 2

2022 rama sdmc nmedx 3

2022 rama sdmc nmedx 4

2022 rama sdmc nmedx 5

Ramathibodi Hospital Sigma VP

Congratulations to Ramathibodi Hospital for expanding their verification and continuing to provide a world class standard of test results.

Let us know what you're interested in!

Please use this form to request more information about.

Westgard Products and Services.

Invalid Input
Invalid Input
Invalid Input
Invalid Input