Rajavithi Hospital Laboratory Sigma Verification of Performance

Rajavithi Hospital Laboratory sustains their membership in the Sigma Verification of Performance Program. Re-verified Feb 22nd, 2023

Sigma Verification of Rajavithi Hospital Laboratory

Verification: February 1st, 2021
Duration of Verification: February 22nd, 2023 through February 29th, 2024

 In 2021, Rajavithi Hospital Laboratory joined the Westgard Sigma Verification of Performance Program.

From their application

"Rajavithi Hospital is a 1,200-bed medical center accommodating 40,000 in-patients and 1,000,000 out-patients yearly or a daily average of 4,000 patients, with 200,000 referral patients (both in and out patients). The hospital provides medical service at standard health promotion in tertiary levels and above, including quality referral system. There are more than 200 medical doctors, over 800 professional nurses and specialized staff and over 4,000 other supporting staff who are ready to provide medical services in varied specialties and healthcare dimensions."

Summary of Analyte Performance

Instrument performance in Chemistry were verified.

Chemistry Assay

SN AC02620 verified

SN AC02651 verified

SN AC02652 verified

Albumin

Six Sigma

Six Sigma

Six Sigma

Alkaline Phosphatase

Five Sigma

Four Sigma

Four Sigma

ALT

-

Four Sigma

Four Sigma

AST

-

-

Five Sigma

Bilirubin, Direct

Six Sigma

Six Sigma

Six Sigma

Calcium

Six Sigma

Four Sigma

Five Sigma

Chloride

-

-

Four Sigma

Cholesterol

Six Sigma

Six Sigma

Six Sigma

Creatinine Kinase CK

Six Sigma

-

Six Sigma

Creatinine

Six Sigma

Six Sigma

Six Sigma

Glucose

-

Four Sigma

Five Sigma

HDL

Six Sigma

Six Sigma

Six Sigma

Iron

-

-

Four Sigma

Magnesium

Six Sigma

Six Sigma

Six Sigma

Phosphorous

Four Sigma

-

Four Sigma

Potassium

Six Sigma

Six Sigma

Six Sigma

Protein, Total

Six Sigma

Five Sigma

Six Sigma

Triglycerides

Six Sigma

Six Sigma

Six Sigma

UIBC

Four Sigma

-

Four Sigma

Uric Acid

-

Four Sigma

Four Sigma

continuing...

Chemistry Assay

SN AC02653 verified

SN AC02654 verified

SN AC02655 verified

Albumin

Five Sigma

Six Sigma

Six Sigma

Alkaline Phosphatase

-

Four Sigma

Five Sigma

ALT

-

Five Sigma

Four Sigma

AST

Four Sigma

Five Sigma

Four Sigma

Bilirubin, Direct

Six Sigma

Six Sigma

Six Sigma

Calcium

Six Sigma

Six Sigma

Six Sigma

Chloride

Five Sigma

Six Sigma

Four Sigma

Cholesterol

Six Sigma

Six Sigma

Six Sigma

Creatinine

Six Sigma

Six Sigma

Six Sigma

Glucose

Six Sigma

Five Sigma

Five Sigma

HDL

Six Sigma

Five Sigma

Six Sigma

Magnesium

Six Sigma

Six Sigma

Six Sigma

Phosphorous

-

Four Sigma

Four Sigma

Potassium

Six Sigma

Six Sigma

Six Sigma

Protein, Total

Six Sigma

Six Sigma

Six Sigma

Triglycerides

Five Sigma

Six Sigma

Five Sigma

Uric Acid

Four Sigma

Four Sigma

Four Sigma

Six Sigma: World Class Quality. Possible to use 3s to 3.5s limits and a minimum of controls

Five Sigma: Excellent Quality. Possible to use 3s limits or a 1:3s/2:2s/R:4s Westgard Rule

Four Sigma: Good Quality. Possible to use 1:3s/2:2s/R:4s/4:1s Westgard Rule

 Visual Summary of Performance of Rajavithi Hospital Laboratory

2023 Rajavithi re vp NMEDX 1

2023 Rajavithi re vp NMEDX 2

2023 Rajavithi re vp NMEDX 3

2023 Rajavithi re vp NMEDX 4

2023 Rajavithi re vp NMEDX 5

2023 Rajavithi re vp NMEDX 6
 

 Congratulations again to Rajavithi Hospital Laboratory and their staff.

 

 