NGHA Jeddah Sigma Verification of Performance

NGHA Jeddah becomes the second public laboratory in Saudi Arabia to achieve re-verification. Now more than 90 assays across 6 instruments are verified.

National Guard Hospital Administration Jeddah - Sigma Verification of Performance

Original Verification: May 10th, 2016
Duration of Current Verification: July 1st, 2019 through July 31st, 2020

King Abdulaziz Medical City in Jeddah, with a 751 bed capacity, provides state of the art practice of medical care services for the Saudi Arabian population in the Western Region. In addition to that, it promotes and advances understanding of diseases prevention amongst the population. It also initiates, interacts and indulges in the medical bases practice amongst the institutional, local, regional, national and international collegial community.

Since the medical city was founded in July 1982, it has strived to preserve excellence in quality of patient care. It has transformed to become part of King Abdulaziz Medical City-Jeddah.

The verification was completed on their ARCHITECT instruments. While the original verification covered only 1 instrument, the re-verification covers 3 biochemistry instruments and 3 immunoassays.

Chemistry Assay

C8000-1 verified

C8000-2 verified

C8000-3 verified

Albumin

Four Sigma

-

Four Sigma

ALT

Six Sigma

Five Sigma

Five Sigma

Alkaline Phosphatase

-

Six Sigma

Six Sigma

Amylase

Six Sigma

Six Sigma

-

AST

Four Sigma

Four Sigma

Four Sigma

Bilirubin, Direct

Six Sigma

Six Sigma

Six Sigma

Bilirubin, Total

Five Sigma

Six Sigma

Six Sigma

CO2

Four Sigma

-

Four Sigma

Calcium

Six Sigma

Six Sigma

Six Sigma

Cholesterol

Five Sigma

Five Sigma

Six Sigma

Creatinine

Five Sigma

Four Sigma

Five Sigma

GGT

Six Sigma

Six Sigma

Six Sigma

Glucose

Six Sigma

Six Sigma

Six Sigma

Iron

-

Six Sigma

Five Sigma

HDL

Five Sigma

Five Sigma

Five Sigma

IgG

-

Six Sigma

Six Sigma

IgM

-

-

Four Sigma

Lactate

Six Sigma

Six Sigma

Six Sigma

Lipase

Six Sigma

Six Sigma

-

Magnesium

Six Sigma

Six Sigma

Six Sigma

Phosphorous

Five Sigma

Six Sigma

Five Sigma

Potassium

Five Sigma

Five Sigma

Six Sigma

Transferin

-

Six Sigma

Six Sigma

Total Protein

Six Sigma

Six Sigma

Five Sigma

Triglycerides

Six Sigma

Six Sigma

Six Sigma

UIBC

Four Sigma

-

-

Uric Acid

Six Sigma

Six Sigma

Six Sigma

Immunoassays that were verified for the first time:

Immunoassays

I2000-1 Verified

I2000-2 Verified

I2000-3 Verified

Cortisol

Four Sigma

-

-

Digoxin

Four Sigma

-

-

AFP

-

Five Sigma

Six Sigma

PSA

-

Six Sigma

Four Sigma

TSH

-

Four Sigma

Six Sigma

FSH

-

Five Sigma

Four Sigma

hCG

-

Four Sigma

Four Sigma

LH

-

Six Sigma

Six Sigma

Phenytoin

Six Sigma

Five Sigma

-

Progesterone

Five Sigma

-

Five Sigma

Prolactin

-

Four Sigma

Four Sigma

Testosterone

-

-

Four Sigma

TSH

Five Sigma

Five Sigma

-

Vancomycin

Four Sigma

-

-

Performance of NGHA Jeddah

2019 NGHA Jeddah c8000 1 MEDx

2019 NGHA Jeddah c8000 2 MEDx

2019 NGHA Jeddah c8000 3 MEDx

2019 NGHA Jeddah i2000 1 MEDx

2019 NGHA Jeddah i2000 2 MEDx

2019 NGHA Jeddah i2000 3 MEDx

Congratulations to NGHA Jeddah Laboratory on their accomplishment.