This is the 8th edition of data regarding the components of biological variation (intra and inter-individual -CVI and CVG , respectively) which compiles the published papers studying this item in healthy population, up to December 2013. The aim of this work is to provide quality specifications for imprecision, bias and total error to be used in laboratory medicine. The number of analytes with BV data available in this edition is: 357.
IMPORTANT UPDATE: "[T]he BV data on your website is provided by the Analytical Quality Commission of the SEQC....
"The Analytical Quality Commission and ourselves have discussed this and agree that the EFLM database probably will provide estimates of Total allowable error. Furthermore, once the EFLM database is available, the BV database provided by the SEQC should be removed from both your website and the SEQC website. We would therefore not agree to new data being added to the 2014 BV database update. The aim is for the EFLM website to be available within 4-6 months and we will contact you once it has been published. Thank you for your understanding.
Kind regards,
Aasne Krine Aarsand, Sverre Sandberg, Pilar Fernandez Calle, Carmen Perich & Carmin Ricos
On behalf of the Working Group on Biological Variation, EFLM and the Analytical Quality Commission, SEQC, April 26, 2018"
Here are the links to the updated tables:
In this edition 19 new analytes have been added (table 1); however the total number of analytes included here is shortly lower than the presented in previous edition, because components not directly measured but calculated from other analytes (i.e urine albumin/creatinine ratio, or serum LDL cholesterol calculated).
Some changes with respect to the 7th edition have been made; they are:
A brief summary: first edition was presented at the Stockholm international consensus conference on Strategies to Set Global Analytical Quality Specifications in Laboratory Medicine, was published in the Scan J Clin Lab Invest 1999;59:475-586 and also published on this website in June 2000. Successively, database has been updated every two years, up to the present 8th edition. Number of analytes included evolved from 316 up to the present 357. This information is also published at the SEQC website (http://www.seqc.es) in Spanish language.
| Table 1. New analytes added to the 2014 edition | |||
|---|---|---|---|
| System | Analyte | System | Analyte |
| Serum | Carnitine, acyl free | Plasma | Parathyroid Hormone (PTH) |
| Plasma | Cortisol | Serum | Plasmatic A Protein - Pregnancy associated (PAPP-A) |
| Serum | C reactive-protein ultrasensitive | Plasma | Prolactin |
| Plasma | D-Dimer (MoM) | Serum | Receptor for advanced glycated end-products (RAGE) |
| Plasma | γ-Fibrinogen | Plasma | Testosterone |
| San- | Hemoglobin A2 | Plasma | Thyrotropin (TSH) |
| Serum | Hyaluronic acid | Plasma | Thyroxin, free (FT4) |
| Serum | Inhibin B | Plasma | Triiodothyronine (T3) |
| Serum | Kallicrein | Plasma | Troponin I |
| Serum | LDL-Cholesterol, small dense | ||
| Table 2. Analytes with new papers added in this edition | |||
|---|---|---|---|
| System | Analyte | System | Analyte |
| Serum | α2-Macroglobulin | Serum | HDL Cholesterol |
| Serum | Alanine aminotransferase (ALT) | Serum | LDL Cholesterol |
| Serum | Albumin | Blood | Leukocytes, count |
| Serum | Aspartate aminotransferase (AST) | Serum | Lutropin (LH) |
| Serum | Bilirubin | Blood | Mean corpuscular hemoglobin (MCH) |
| Serum | Calcium | Blood | Mean Corpuscular Hemoglobin Concentration (MCHC) |
| Serum | Chloride | Blood | Mean Corpuscular Volume (MCV) |
| Serum | Cholesterol | Blood | Platelet |
| Serum | Creatinine | Serum | Potassium |
| Blood | Erythrocytes, count | Serum | Protein |
| Serum | Estradiol | Serum | Sex Hormone Binding Globulin (SHBG) |
| Serum | Folitropin (FSH) | Serum | Sodium |
| Serum | Alkaline phosphatase | Serum | Testosterone |
| Serum | Phosphate | Serum | Triglyceride |
| Serum | γ-Glutamyl transferase (GGT) | Serum | Troponin I |
| Serum | Glucose | Serum | Urate |
| Blood | Hematocrit | Serum | Urea |
| Blood | Hemoglobin | ||
- Annex I, showing quality specifications, has a new column with the number of articles compiled for each analyte. This information also appears in Annex II; however, the number of consultations received dealing with this item seemed us to indicate that many readers did not realize about annex II.
This column highlights the robustness of CVI and CVG described (median of values compiled for each analyte). For example, there are 58 cholesterol CVI values coming from 46 papers, which results to a median of CVI=5.9% and a confidence interval (p<0.05) of 0.43, with values ranging from 2.4% to 9.7%. AST has 21 data coming from de 13 papers, with a median of CVI = 12.3%, a confidence interval of 2.02% and values ranging between 4.7 and 24.2%. There are many analytes with a reduced number of papers published, thus the CVI and CVG estimated are quite poor and further studies should be made.